Control 30 Panels
Hemsec Control 30 insulated panels are engineered for thin profile and cost-effective solutions, ideal for controlled environments.
These versatile panels offer excellent thermal insulation and fire performance at selected thicknesses, making them a perfect solution for ambient, chilled, and freezer areas, as well as cold storage and food preparation spaces.
Hemsec Control 30 panels are particularly suited for when temperature control and is critical.

Control 30 Insulated Panels
For general food production, Control 30 is an internal insulated panel with steel facings, and provides fire performance at selected thicknesses for additional assurance and thermal insulation.
- Ideal for ambient, chilled or freezer areas where non-intensive cleaning is required.
- Recommended for all temperature ranges between -40 to +50 °C.
- Long cover width of 1155mm helps reduce your panel quantity requirements.

Hemsec Control 30 panels are particularly suited for environments where both temperature control and safety are critical, such as in food processing, storage, and distribution facilities. Their lightweight construction makes them easy to handle, reducing installation time and costs, while their high-quality finish enhances the visual appeal of any space.
Their slim profile ensures maximum space efficiency while delivering high performance in temperature-controlled settings. For insulated solutions in controlled environments, Hemsec Control 30 Insulated Panels offer performance and cost-effectiveness. Selected thicknesses are independently assessed and approved under the LPCB LPS 1208 scheme, providing fire performance as an enhancement to the core thermal and structural properties of the system and offering additional assurance to your building.
Applications
These temperature-controlled insulated panel solutions are typically used within the food and drink industry, for applications such as:
Freezer Applications.
Chilled Storage & Warehousing.
Food Processing and Preparation.
Control 30 Insulated Panels – Technical info
We aim to provide you with easy-to-follow, relevant technical information, suited to various applications.
Whilst we are confident the below data will help you specify, design and build your project using our Hemsec Clean panels, we always encourage further conversations around your project-specific requirements. This can make the most of our panel’s capabilities, allowing us to tailor our technical details with a project-specific guarantee.
Not yet at build stage? Great, it’s best to discuss requirements as early as possible to ensure we get the panels you need, when you need them…
Panel Data
Chill & Ambient Applications (Above 0 °C):
| Panel Thickness (mm) | Min. Panel Length (m) | Max. Single Span Wall Height * (m) | Max. Single Span Ceiling * (m) | Thermal Transmittance U W/M2K *** | Deflection Temp. Difference * | Weight Kg/m2 (0.5/0.5) |
|---|---|---|---|---|---|---|
| 100 | 2.0 | Refer to Data Sheet | Refer to Data Sheet | 0.20 | 18°C | 11.60 |
| 125 | 2.0 | Refer to Data Sheet | Refer to Data Sheet | 0.16 | 18°C | 12.50 |
| 150 | 2.0 | Refer to Data Sheet | Refer to Data Sheet | 0.13 | 18°C | 13.40 |
The stated temperature difference may be increased to allow for negative temperature zones (i.e. Freezers) however this will affect the stated spans above, refer to the Freezer Applications table below for further guidance.
Max. Single ceiling spans are based on 0.9kN point load at mid-span and 0.25kN/m2 UDL (Hemsec strongly recommend referring to our Ceiling Care document for greater detail). Minimum bearing/support of 50mm at panel ends. Consult Hemsec for further information on permitted bearing loads and edge supports.
Panels are manufactured to bespoke lengths starting at the stated minimums above; maximum lengths stated may be increased upon referral to Hemsec up to a manufacturing capability limit of 15m**
** Hemsec should be consulted on any panel lengths greater than the maximum stated in the above table due to the difficulties faced when handling and on installation. Spans greater than 12.50m(Walls) / 8.80m(Ceilings) typically captured within the Control 60 product ranges.
*** Calculated using the method required by the Building Regulations Part L2 (England & Wales) and Building Standards Part J (Scotland).
Thermal transmittance based on λ mean = 0.02038 W/Mk.
Freezer Applications (Below 0 °C):
| Panel Thickness (mm) | Min. Panel Length (m) | Max. Single Span Wall Height * (m) | Max. Single Span Ceiling * (m) | Thermal Transmittance U W/M2K *** | Deflection Temp. Difference * | Weight Kg/m2 (0.5/0.5) |
|---|---|---|---|---|---|---|
| 100 | 2.0 | Refer to Data Sheet | Refer to Data Sheet | 0.20 | 18°C | 11.60 |
| 125 | 2.0 | Refer to Data Sheet | Refer to Data Sheet | 0.16 | 18°C | 12.50 |
| 150 | 2.0 | Refer to Data Sheet | Refer to Data Sheet | 0.13 | 18°C | 13.40 |
The stated temperature difference may be increased to allow for negative temperature zones (i.e. Freezers) however this will affect the stated spans above, refer to the Chill & Ambient Applications table above for further guidance.
Max. Single ceiling spans are based on 0.9kN point load at mid-span and 0.25kN/m2 UDL (Hemsec strongly recommend referring to our Ceiling Care document for greater detail). Minimum bearing/support of 50mm at panel ends. Consult Hemsec for further information on permitted bearing loads and edge supports.
Panels are manufactured to bespoke lengths starting at the stated minimums above; maximum lengths stated may be increased upon referral to Hemsec up to a manufacturing capability limit of 15m**
** Hemsec should be consulted on any panel lengths greater than the maximum stated in the above table due to the difficulties faced when handling and on installation. Spans greater than 10.50m(Walls) / 7.49m(Ceilings) typically captured within the Control 60 product ranges.
*** Calculated using the method required by the Building Regulations Part L2 (England & Wales) and Building Standards Part J (Scotland).
Thermal transmittance based on λ mean = 0.02038 W/Mk.
Cover Width: 1155mm
Insulation Core:
A rigid Polyisocyanurate insulation core, provides the following benefits:
- Closed cell
- HCFC free
- Zero ozone depletion potential (ODP)
Panel Joint: Tongue and groove panel joint for excellent vapour resistance and thermal performance.
Finishes
Steel Facing Options:
| Facing Steel Finishes* | Internal Steel Face | External Steel Face | Steel Substrate (nominal) | Paint Thickness µm (nominal) | Laminate Thickness µm (nominal) |
|---|---|---|---|---|---|
| Foodsafe Laminate | ✔ | ✔ | 0.5mm Z225 HDG | – | 120 |
| Foodsafe Polyester | ✔ | ✔ | 0.5mm Z225 HDG | 25 | – |
| Primer/Liner | ✔ | ✔ | 0.5mm Z225 HDG | 7-10 | – |
Facing Profile Options:
- Smooth
- 100 Rib
- Micro Rib (one face only)
Specification Information
For full product information, please download our product data sheet.
Air Leakage: Panel joint air-tightness = 0.01 m3/m2/hr at 50 Pa when tested to EN 12114 in accordance with BS EN 14509: 2013.
Acoustics: All panels have a predicted figure weighted sound reduction Rw = 26dB.
Quality & Durability: Hemsec metal-faced panels are manufactured from the highest quality raw materials using state-of-the-art production equipment. Our production strictly follows rigorous quality control standards (complying with an approved BS EN ISO 9001:2015 QMS standard) ensuring long-term durability and service life.
Guarantees & Warranties: Hemsec can offer panel performance guarantees based on your project-specific requirements.
Please contact the Hemsec team to discuss your requirements.
Fire Data
Reaction to fire:
White Foodsafe Laminate (WFSL) faced panels have a reaction to fire according to EN 13501-1 of: B, s2, d0. (50mm exclusion = B, s3, d0.)
Fire resistance:
LPCB LPS 1208 Cert:558a
- LPS Rating FR30 for selected thicknesses with maximum unsupported span 4m (walls) & 7.5m (ceilings).
BS EN 13501-2: 2016
- 125-150mm thicknesses achieve EI30 under Extended field of Application BS EN 15254-5: 2009 with maximum unsupported span 12m (walls).
Hemsec Control 50mm and 80mm panels are classed as non fire-rated.
Detailing
Rebates & Thermal Breaks:
- Optional top rebates are available to suit your ceiling panel thickness. 80mm panels available with a 40mm landing depth. 100 – 200mm thick panels with a 50mm landing depth.
- Bottom thermal breaks are available to one side only, varying in depth between 75 – 300mm.
- Rebates and thermal breaks are not applicable to our 50mm panels.